• Designed to maintain marination at a temperature of 34ºF or colder in the holding tank
  • Typical flowrate is based on 40 GPM with a 6-degree temperature decrease and an internal velocity of approximately 7 ft./sec which allows for both adequate cooling velocity and a velocity for CIP circulation.
  • Load calculations based on refrigerant temp being 10 degrees colder than target process temp.
  • ASME Certified to 250 PSI stainless steel construction
  • Heat transfer design pressure: 250PSIG@-20 to 300F
  • Heat transfer surface will be designed, fabricated, and stamped to ASME section VIII, latest edition, and latest addendum.
  • Control of HEX is integrated into the mixing system controls
  • Liquid contact surfaces are 4B polished SS with one-piece end cap including sanitary clamps, ferrules, and gaskets.
  • Heat Exchanger is insulated and jacketed with stainless.
  • Does not include refrigeration valves
  • Mix/Chill Tanks come in both jacketed and non-jacketed design. Jacketed tanks can be designed to use NH3 or Glycol as cooling media. Non-Jacketed tank systems are designed to be used in conjunction with a heat exchanger to maintain temperatures for processing.